logo
Home ProductsHospital Medical Equipment

Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment

Certification
Good quality Patient Monitoring Equipment for sales
Good quality Patient Monitoring Equipment for sales
great working items throughout the site. and fast delivery all the way to canada. good job guys

—— S Matheson

Wonderful package and great service got my products in 5 days ....Australia,sydney

—— AndySereika

Really good price and great packing,love your job

—— Michael Edw

Amazing job ! Thank you bro! My clients are all satisfied with the results, i'll keeping buy from you all the time.

—— Jason M.

I'm Online Chat Now

Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment

China Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment supplier
Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment supplier Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment supplier

Large Image :  Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment

Product Details:

Place of Origin: China(mainland)
Brand Name: Darppon
Certification: CE ISO9001 ISO13485
Model Number: KHA-220

Payment & Shipping Terms:

Minimum Order Quantity: 1 Unit/Units
Price: US $4000-4200 / Unit
Packaging Details: Standard export packing
Delivery Time: 5-7 working days
Payment Terms: Western Union ,T/T
Supply Ability: 500 Unit/Units per Month
Detailed Product Description
Type: Discrete Automatic, Random Access Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 160tests/hour (without ISE) Spectrometric Method: After Spectrometric Method
Wavelength: 8 Wavelengths, Selectable Among 340-800nm Absorption Range: 0-4.0Abs
Optical System: Integrated Full Closed Optical System Test Method: End-point, Fixed-time (two Point Method), Kinetic
Reaction Tray: 81 UV Cuvettes (disposable) Reaction Temperature: 37±0.2°C
Highlight:

Modern Medical Equipment

,

Medical Diagnostic Equipment

News 2017 semi automatic biochemistry analyzer test medical equipment

 

Technical Feature

Performance

 

Type Discrete Automatic
Principle Absorption Spectrometry, Turbidimetry
Throughput Constant 120tests/hour (without ISE)
Test Method End-point, Fixed-time, kinetic
Support dual reagents/double wavelength
Test sequence

Run tests in strict accordance with sample sequence,

Insert emergency at any time

Online Sample 30 samples/ batch, unlimited batch input
Reaction Time Max 15minutes
Reaction Volume Mini 150μl
Cuvette 81 cuvettes

 

Optical System

Light Source: Halogen-tungsten lamp, 12V/20W

More than 2000hrs service time

Spectrometric Method: After spectrometric method

Wavelength: 8 wavelengths, selectable among 340-800nm

Absorption Range: 0-4.0Abs

Optical System: Integrated full closed optical system

 

Sample system

Sample Tray 30 positions
Sample Volume 2-100μl, 0.1μl by step
Sample Probe Liquid level detection, anti-collision protection and inventory checking,have automatic stop and alarm prompt for an obstacle
Probe Cleaning Automatic washing for both interior and exterior
Others
Water Consumption less than 3L/hour
Power Supply AC 220 ±22V 50HZ ±1HZ
Power Max 200VA
Ambient Temperature 10°C-30°C

 

Reagent System

Reagent Volume: 20-500μl, 1μl by step

Reagent Tray: 60 positions, open system

Reagent Probe: : Liquid level detection, anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle

Probe Cleaning: Automatic washing for both interior and exterior

Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available

dead volume <1ml

 

Temperature Control System

Heating Mode: Solid constant temperature closed direct heating

Equilibrium Time: less than 3minutes

Reaction Temperature: 37±0.2°C

Temperature Fluctuation: ± 0.2°C

 

Control and Calibration

Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial

Automatically check calibration curve and select the calibration type with the best fitting

QC Type: Real time QC, QC in one day, QC between days;

QC chart: L-J, Cumulative, Twin Plot

QC Rules: Multi-rule; default: Westguard

Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.

Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, front belt detection,reaction limit inspection, reagent blank absorbance judgment

Operation Unit

Operation System: Windows operation system

Database: SQL Server

Data Storage: Automatic storage and backup, permanently preserve all kinds of data

Print Content: Print content can be customized

Print Format: Provide a variety of print format

Semi Automatic Turbidimetry Biochemistry Analyzer Test Medical Equipment

Contact Details
Wuhan Darppon Medical Technology Co., Ltd

Contact Person: Mr. hu

Tel: 86-27-87053356

Fax: 86-27-87053356

Send your inquiry directly to us (0 / 3000)